力士乐REXROTH比例阀故障原因和解决办法
德国REXROTH比例阀***代理商
①REXROTH由于插头组件的接线插座[基座)老化、接触不良以及电磁铁引线脱焊等原因,导致比例电磁铁不能工作(不能通人电流)。此时可
用电表检测,如发现电阻无限大,可重新将引线焊牢,修复插座并将插座插牢。
②线圃组件的故障有线圈老化、线圉烧毁、线圈内部断线以及线圈温升过大等现象。线圈温升过大会造成比例电磁铁的输出力不够,其余会使
比例电磁铁不能工作。
力士乐对于线圈温升过大,可检查通人电流是否过大,线圈是否漆包线绝缘不良,(方向控制阀)阀芯是否因污物卡死等,一一査明原因并排除
之;对于断线、烧坏等现象,须更换线圃。
③衔铁组件的故障主要有衔铁因其与导磁套构成的摩擦副在使用过程中磨损,导致阀的力滞环增加。还有推杆导杆与衔铁不同心,也会引起力
滞环增加,必须排除之。
④因焊接不牢,或者使用中在力士乐比例阀脉冲压力的作用下使导磁套的焊接处断裂,使比例电磁铁丧失功能。
⑤导磁套在冲击压力下发生变形,以及导磁套与衔铁构成的摩擦副在使用过程中磨损,导致力士乐比例阀出现力滞环增加的现象。
⑥力士乐比例放大器有故障,导致比例电磁铁不工作。此时应检查放大器电路的各种元件情况,消除比例放大器电路故障。
⑦力士乐比例放大器和电磁铁之间的连线断线或放大器接线端子接线脱开,使比例电磁铁不工作。此时应更换断线,重新连接牢靠。